Part Number: 102744 | Manufacturer: Dytek Laboratories | NSN: 5950-00-276-5448 (5950002765448) |
Item Name : transformer power | CAGE Code: 54519 | FSC : 5950 Coils and Transformers |
We currently have Part Number 102744 with NSN 5950002765448 in stock. This component is manufactured by Dytek Laboratories under CAGE Code 54519 and described as Transformer Power..
To get a quote , all you need to do is fill out the form for 102744 part provided below. Make sure that you fill in all the necessary details, this will help us provide the quote that meets your needs. Once you submit the form, one of our experienced representatives will get back to you with a quote in 15 minutes or less.
With over 100 million parts sold, we are among the reputed independent distributors within the United States. Sourcingstreamlined.com has over 26 different distinct federal supply code categories, with more than 10 million national stock numbers from 5,000 leading manufacturers.
A national stock number, also known as an NSN, part bears an official label indicating its procurement, storage, and stocking within the Federal supply system. NSN parts are an essential part of the military and defense logistics supply chain and can have multiple part numbers under it depending on whether it has multiple manufacturers for the same part. Part number 102744 belongs to the Federal Supply Group 5950 Coils And Transformers.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-276-5448 Item Description: Transformer Power | 5950 | 002765448 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
102744 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.375 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.375 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.125 INCHES MINIMUM SINGLE GROUP AND 0.125 INCHES MINIMUM SINGLE GROUP AND 0.187 INCHES MAXIMUM SINGLE GROUP0.187 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENTTHREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA AND DELTA-DELTA AND DELTA-WYEDELTA-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.000 INCHES MAXIMUM3.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.750 INCHES MAXIMUM2.750 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.875 INCHES MINIMUM AND 3.875 INCHES MINIMUM AND 4.125 INCHES MAXIMUM4.125 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS170.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUPSLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 11 SECONDARY SINGLE COMPONENT11 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 17.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY17.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 17.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY17.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 17.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY17.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 17.50 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY17.50 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 180.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 180.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; ELEVEN SECONDARY WINDINGS,NEUTRAL TAP ON FIRST THRU NINTH SECONDARIESONE PRIMARY WINDING; ELEVEN SECONDARY WINDINGS,NEUTRAL TAP ON FIRST THRU NINTH SECONDARIES |
TTQY | TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, PLUG AND 43 TAB, SOLDER LUG |
All Orders are Fulfilled in the USA.
All shipments must comply with USA export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Remember Us the Next Time You are Looking for NSN Parts.
Request for Quote