Part Number: K4946 | Manufacturer: Keytronics Inc | NSN: 5950-00-946-3305 (5950009463305) |
Item Name : transformer power | CAGE Code: 51181 | FSC : 5950 Coils and Transformers |
We currently have Part Number K4946 with NSN 5950009463305 in stock. This component is manufactured by Keytronics Inc under CAGE Code 51181 and described as Transformer Power..
To get a quote , all you need to do is fill out the form for K4946 part provided below. Make sure that you fill in all the necessary details, this will help us provide the quote that meets your needs. Once you submit the form, one of our experienced representatives will get back to you with a quote in 15 minutes or less.
With over 100 million parts sold, we are among the reputed independent distributors within the United States. Sourcingstreamlined.com has over 26 different distinct federal supply code categories, with more than 10 million national stock numbers from 5,000 leading manufacturers.
A national stock number, also known as an NSN, part bears an official label indicating its procurement, storage, and stocking within the Federal supply system. NSN parts are an essential part of the military and defense logistics supply chain and can have multiple part numbers under it depending on whether it has multiple manufacturers for the same part. Part number K4946 belongs to the Federal Supply Group 5950 Coils And Transformers.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-946-3305 Item Description: Transformer Power | 5950 | 009463305 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
K4946 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.190 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.210 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.510 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.530 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO TWO PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-OPEN DELTA |
ADAQ | BODY LENGTH | 2.860 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.250 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.300 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.02 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 11.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 25.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 825.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 38.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 133.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 0.638 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 22.8 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 26.5 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 9.3 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 16.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 19.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 54.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 70.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 20.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 37.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 94.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 114.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 3.47 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 58.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; FIVE SECONDARY WINDINGS WITH FIRST,SECOND,FOURTH,AND FIFTH WINDINGS CENTER TAPPED |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 23 TAB, SOLDER LUG |
All Orders are Fulfilled in the USA.
All shipments must comply with USA export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
We Hope You Remember Us the Next Time You are Looking for NSN Parts.
Request for Quote